Macchina ad ultrasuoni Doppler a colori portatili per ostetricia
$2100-3500 /Set/Sets
Tipo di pagamento: | T/T |
Incoterm: | FOB |
Quantità di ordine minimo: | 1 Set/Sets |
Trasporti: | Ocean,Land,Air,Express |
Porta: | Shenzhen,Ningbo,Shanghai |
$2100-3500 /Set/Sets
Tipo di pagamento: | T/T |
Incoterm: | FOB |
Quantità di ordine minimo: | 1 Set/Sets |
Trasporti: | Ocean,Land,Air,Express |
Porta: | Shenzhen,Ningbo,Shanghai |
Modello: MDK-680
marchio: Ultrasuoni uniti
Luogo D'origine: Cina
Tipo Di Potere: Elettricità
Servizio Di Garanzia: 1 anno
Assistenza Post-vendita: Pezzi di ricambio gratuiti, Supporto tecnico in linea
Materiale: metallo, plastica
Classificazione Dei Dispositivi Medici: Classe II
Color: white
marchio: United Ultrasound
Monitor Size: 12 inch
Gray Scale: 256 levels
Depth: ≥300mm
Channels: 32
Operating System: Windows 7
Unità vendibili | : | Set/Sets |
Tipo pacchetto | : | Cartone |
The file is encrypted. Please fill in the following information to continue accessing it
Macchina ad ultrasuoni Doppler a colori portatile per ostetricia (MDK-680)
L'esame ad ultrasuoni a colori ostetrici è principalmente per verificare lo sviluppo del feto in utero. L'ecografia a colori può essere utilizzata per misurare il doppio diametro parietale fetale, la circonferenza della testa, la circonferenza addominale e la lunghezza del femore per giudicare le dimensioni del feto. Inoltre, si possono osservare la maturità placentare, il fluido amniotico, il movimento del cuore fetale e se ci sono evidenti deformità di sviluppo fetale
Cinque scopi di B-ultrasound durante la gravidanza
1, per vedere se la crescita e lo sviluppo del bambino fetale è coerente con la settimana gestazionale;
2. Guarda la sicurezza del feto in utero;
3, per vedere se il bambino è deformato;
4. prevedere la probabilità di nascita prematura;
5, per vedere se soffrirai di ipertensione indotta dalla gravidanza.
Quante volte dovrebbe essere fatto l'ecografia B di routine durante la gravidanza?
Se tutto è normale durante la gravidanza, di solito, la madre in attesa farà da 2 a 3 esami di ultrasound durante la gravidanza, rispettivamente in 18-24 settimane di gravidanza, 36 settimane di gravidanza dopo. Il tempo di esame degli ultrasuoni di gravidanza non è troppo presto, in circostanze normali, è meglio non fare a ultrasuoni B entro 12 settimane dalla gravidanza, specialmente all'inizio della gravidanza.
I nostri prodotti:
Scanner ad ultrasuoni in bianco e nero
Scanner ad ultrasuoni Doppler a colori
Scanner ad ultrasuoni veterinari
No. |
Item |
Index |
<1> |
Depth |
≥300mm |
<2> |
Lateral Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
<3> |
Axial Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
<4> |
Blind Area |
≤5 mm |
<5> |
Geometry Position Precision |
horizontal≤10% vertical≤10% |
<6> |
Language |
English/Chinese |
<7> |
Channels |
32 |
<8> |
Displayer |
12” LED |
<9> |
External Display |
PAL, VGA, USB |
<10> |
Gray Scale |
256 levels |
<11> |
Voltage |
AC220V ±10% |
<12> |
Operating System |
Windows 7 |
<13> |
Scanning Mode |
B, B/B, 4B, B/M, M, B+C, B+D, B+C+D, PDI, CF, PW |
<14> |
Probe |
Probe sockets: 2 Probe frequency: 2.0MHz ~ 10.0MHz, 8-step frequency conversion |
<15> |
Adjustment parameters of color blood flow image |
Doppler frequency, sampling frame position and size, baseline, color gain, deflection angle, wall filtering, cumulative times, etc |
<16> |
Signal processing |
With dynamic filtering and quadrature demodulation With total gain adjustment Gain adjustment: 8-segment TGC The total gain of Type B, Type C and Type D can be adjusted respectively B/W image gain and color blood flow gain are adjustable respectively |
<17> |
Doppler |
Doppler baseline adjustment level 6 Pulse repetition frequency can be adjusted separately: CFM PWD With D linear speed regulation |
<18> |
Digital beam forming |
Continuous dynamic focusing of digital beam forming image Full range dynamic aperture of image Dynamic tracing of the whole image Weighted Sum of Image Whole Process Receiving Delay Support half step scanning and ± 10 ° linear receiving deflection angle Multi beam parallel processing technology |
<19> |
Basic measurement and calculation function |
Basic measurement in mode B: distance, angle, perimeter and area, volume, stenosis rate, histogram, cross-section |
Basic measurement of M-mode: heart rate, time, distance and speed |
||
Doppler measurement: time, heart rate, speed, acceleration |
||
<20> |
Obstetric measurement and calculation function |
G.A, EDD, BPD-FW, FL, AC, HC, CRL, AD, GS, LMP,HL,LV,OFD |