Macchina ad ultrasuoni Doppler a colori portatile per un piccolo organo
$2100-3500 /Set/Sets
Tipo di pagamento: | T/T |
Incoterm: | FOB |
Quantità di ordine minimo: | 5 Set/Sets |
Trasporti: | Ocean,Land,Express,Air |
Porta: | Shenzhen,Ningbo,Shanghai |
$2100-3500 /Set/Sets
Tipo di pagamento: | T/T |
Incoterm: | FOB |
Quantità di ordine minimo: | 5 Set/Sets |
Trasporti: | Ocean,Land,Express,Air |
Porta: | Shenzhen,Ningbo,Shanghai |
Modello: MDK-680
marchio: Ultrasuoni uniti
Luogo D'origine: Cina
Tipo Di Potere: Elettricità
Servizio Di Garanzia: 1 anno
Assistenza Post-vendita: Pezzi di ricambio gratuiti, Supporto tecnico in linea
Materiale: metallo, plastica
Classificazione Dei Dispositivi Medici: Classe II
marchio: United Ultrasound
Monitor Size: 12 inch
Gray Scale: 256 levels
Depth: ≥300mm
Channels: 32
Operating System: Windows 7
Color: black
Unità vendibili | : | Set/Sets |
Tipo pacchetto | : | Cartone |
The file is encrypted. Please fill in the following information to continue accessing it
Macchina ad ultrasuoni Doppler a colori portatile per organo piccolo (MDK-680)
Nei piccoli organi, come la tiroide, la ghiandola mammaria e il bulbo oculare, gli ultrasuoni colorati hanno evidente precisione diagnostica.
Da un certo punto di vista, la sonda a 10 MHz è stata più chiara del normale Doppler in bianco e nero su 5 MHz e la sonda è molto più chiara. La diagnosi e la diagnosi differenziale delle lesioni tiroidee si basano principalmente sull'afflusso di sangue interno della tiroide, tra cui l'immagine ipertiroidismo è la più tipica e specifica.
Il gozzo semplice non ha mostrato cambiamenti significativi rispetto al normale flusso sanguigno tiroideo. La tiroidite subacuta, la tiroidite di Hashimoto tra i due, può essere distinta e attraverso noduli e la situazione del flusso sanguigno periferico può essere ben distinto gozzo nodulare, adenoma tiroideo e carcinoma della tiroide Alcune capacità economiche possono fare ultrasuoni colorano ulteriori diagnosi.
L'ecografia del colore mammario è utilizzata principalmente nella diagnosi differenziale del fibroma mammario e del carcinoma mammario e il bulbo oculare ha principalmente un valore migliore nella diagnosi di malattie vascolari del bulbo oculare.
I nostri prodotti:
Scanner ad ultrasuoni in bianco e nero
Scanner ad ultrasuoni Doppler a colori
Scanner ad ultrasuoni veterinari
No. |
Item |
Index |
<1> |
Depth |
≥300mm |
<2> |
Lateral Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
<3> |
Axial Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
<4> |
Blind Area |
≤5 mm |
<5> |
Geometry Position Precision |
horizontal≤5% vertical≤5% |
<6> |
Language |
English/Chinese |
<7> |
Channels |
32 |
<8> |
Displayer |
12” LED |
<9> |
External Display |
PAL, VGA, USB |
<10> |
Gray Scale |
256 levels |
<11> |
Voltage |
AC220V ±10% |
<12> |
Operating System |
Windows 7 |
<13> |
Scanning Mode |
B, B/B, 4B, B/M, M, B+C, B+D, B+C+D, PDI, CF, PW |
<14> |
Probe |
Probe sockets: 2 Probe frequency: 2.0MHz ~ 10.0MHz, 8-step frequency conversion |
<15> |
Adjustment parameters of color blood flow image |
Doppler frequency, sampling frame position and size, baseline, color gain, deflection angle, wall filtering, cumulative times, etc |
<16> |
Signal processing |
With dynamic filtering and quadrature demodulation With total gain adjustment Gain adjustment: 8-segment TGC The total gain of Type B, Type C and Type D can be adjusted respectively B/W image gain and color blood flow gain are adjustable respectively |
<17> |
Doppler |
Doppler baseline adjustment level 6 Pulse repetition frequency can be adjusted separately: CFM PWD With D linear speed regulation |
<18> |
Digital beam forming |
Continuous dynamic focusing of digital beam forming image Full range dynamic aperture of image Dynamic tracing of the whole image Weighted Sum of Image Whole Process Receiving Delay Support half step scanning and ± 10 ° linear receiving deflection angle Multi beam parallel processing technology |
<19> |
Basic measurement and calculation function |
Basic measurement in mode B: distance, angle, perimeter and area, volume, stenosis rate, histogram, cross-section |
|
|
Basic measurement of M-mode: heart rate, time, distance and speed |
|
|
Doppler measurement: time, heart rate, speed, acceleration |