Macchina ad ultrasuoni Doppler a colori portatili per l'addome
$2100-3500 /Set/Sets
Tipo di pagamento: | T/T |
Incoterm: | FOB |
Quantità di ordine minimo: | 5 Set/Sets |
Trasporti: | Ocean,Land,Air,Express |
Porta: | Shenzhen,Ningbo,Shanghai |
$2100-3500 /Set/Sets
Tipo di pagamento: | T/T |
Incoterm: | FOB |
Quantità di ordine minimo: | 5 Set/Sets |
Trasporti: | Ocean,Land,Air,Express |
Porta: | Shenzhen,Ningbo,Shanghai |
Modello: MDK-680
marchio: Ultrasuoni uniti
Color: white
marchio: United Ultrasound
Monitor Size: 12 inch
Gray Scale: 256 levels
Depth: ≥300mm
Channels: 32
Operating System: Windows 7
Luogo D'origine: Cina
Tipo Di Potere: Elettricità
Servizio Di Garanzia: 1 anno
Assistenza Post-vendita: Pezzi di ricambio gratuiti, Supporto tecnico in linea
Materiale: metallo, plastica
Classificazione Dei Dispositivi Medici: Classe II
Unità vendibili | : | Set/Sets |
Tipo pacchetto | : | Cartone |
The file is encrypted. Please fill in the following information to continue accessing it
Macchina ad ultrasuoni Doppler a colori portatile per l'addome (MDK-680)
È usato principalmente nel fegato e nei reni, ma ha un certo valore diagnostico ausiliario per distinguere lesioni benigne e maligne nella cavità addominale, il cancro della cistifellea da grandi polipi, l'infiammazione cronica e grave e la differenza tra dotto biliare comune e arteria epatica.
L'ecografia a colori può essere utilizzata per determinare le dimensioni del lume, la velocità e la direzione del flusso interno e la creazione di circolazione collaterale nella cirrosi epatica. Per la sclerosi nodulare e il carcinoma epatico diffuso, che sono estremamente difficili da distinguere tra bianco e nero, può facilitare la diagnosi differenziale mediante esplorazione ad alta frequenza ed esplorazione dello spettro del flusso sanguigno.
Per la diagnosi differenziale di spazio epatico benigno e maligno che occupa lesioni, cisti e vari tumori artero -venosi hanno un migliore valore diagnostico. Il carcinoma epatico primario e il carcinoma epatico secondario possono anche essere distinti dall'afflusso di sangue interno.
L'ecografia a colori è utilizzata principalmente nei reni per le malattie vascolari renali. Come accennato in precedenza, quando le manifestazioni cliniche sono ematuria settale e indolore, la causa non può essere trovata, ci sono forti segni di adattamento. Per la stenosi dell'arteria renale, una delle cause comuni dell'ipertensione secondaria, gli ultrasuoni del colore possono sostanzialmente fare una chiara diagnosi. Quando la portata del sangue alla stenosi era superiore a 150 cm/s, l'accuratezza diagnostica ha raggiunto il 98,6%e la sensibilità era del 100%. D'altra parte, è anche la diagnosi differenziale del carcinoma renale, il carcinoma transitorio del bacino renale e il tumore benigno.
I nostri prodotti:
Scanner ad ultrasuoni in bianco e nero
Scanner ad ultrasuoni Doppler a colori
Scanner ad ultrasuoni veterinari
No. |
Item |
Index |
<1> |
Depth |
≥300mm |
<2> |
Lateral Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
<3> |
Axial Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
<4> |
Blind Area |
≤4 mm |
<5> |
Geometry Position Precision |
horizontal≤5% vertical≤5% |
<6> |
Language |
English/Chinese |
<7> |
Channels |
32 |
<8> |
Displayer |
12” LED |
<9> |
External Display |
PAL, VGA, USB |
<10> |
Gray Scale |
256 levels |
<11> |
Voltage |
AC220V ±10% |
<12> |
Operating System |
Windows 7 |
<13> |
Scanning Mode |
B, B/B, 4B, B/M, M, B+C, B+D, B+C+D, PDI, CF, PW |
<14> |
Probe |
Probe sockets: 2 Probe frequency: 2.0MHz ~ 10.0MHz, 8-step frequency conversion |
<15> |
Adjustment parameters of color blood flow image |
Doppler frequency, sampling frame position and size, baseline, color gain, deflection angle, wall filtering, cumulative times, etc |
<16> |
Signal processing |
With dynamic filtering and quadrature demodulation With total gain adjustment Gain adjustment: 8-segment TGC The total gain of Type B, Type C and Type D can be adjusted respectively B/W image gain and color blood flow gain are adjustable respectively |
<17> |
Doppler |
Doppler baseline adjustment level 6 Pulse repetition frequency can be adjusted separately: CFM PWD With D linear speed regulation |
<18> |
Digital beam forming |
Continuous dynamic focusing of digital beam forming image Full range dynamic aperture of image Dynamic tracing of the whole image Weighted Sum of Image Whole Process Receiving Delay Support half step scanning and ± 10 ° linear receiving deflection angle Multi beam parallel processing technology |
<19> |
Basic measurement and calculation function |
Basic measurement in mode B: distance, angle, perimeter and area, volume, stenosis rate, histogram, cross-section |
|
|
Basic measurement of M-mode: heart rate, time, distance and speed |
|
|
Doppler measurement: time, heart rate, speed, acceleration |
<20> |
Gynecological measurement and calculation function |
Measurement and calculation of uterus, left ovary, right ovary, left follicle, right follicle, etc |
<21> |
Obstetric measurement and calculation function |
G.A, EDD, BPD-FW, FL, AC, HC, CRL, AD, GS, LMP,HL,LV,OFD |
<22> |
Urology measurement and calculation function |
Measurement and calculation of left kidney, right kidney, bladder, residual urine volume, prostate, prostate specific antigen predicted value PPSA, prostate specific antigen density PSAD, etc |
<23> |
Product Size |
289×304×222mm |
<24> |
Carton Size |
395×300×410mm |
<25> |
N.W./ G.W. |
6kg/ 7kg |