Macchina ad ultrasuoni Doppler a colori portatile
$2100-3500 /Set/Sets
Tipo di pagamento: | T/T |
Incoterm: | FOB |
Quantità di ordine minimo: | 5 Set/Sets |
Trasporti: | Ocean,Land,Air,Express |
Porta: | Shenzhen,Ningbo,Shanghai |
$2100-3500 /Set/Sets
Tipo di pagamento: | T/T |
Incoterm: | FOB |
Quantità di ordine minimo: | 5 Set/Sets |
Trasporti: | Ocean,Land,Air,Express |
Porta: | Shenzhen,Ningbo,Shanghai |
Modello: MDK-680
marchio: Ultrasuoni uniti
Luogo D'origine: Cina
Tipo Di Potere: Elettricità
Servizio Di Garanzia: 1 anno
Assistenza Post-vendita: Pezzi di ricambio gratuiti
Materiale: metallo
Classificazione Dei Dispositivi Medici: Classe II
Monitor Size: 12 inch
Channels: 32
Operating System: Windows 7
Brand: United Ultrasound
Gray Scale: 256 levels
Depth: ≥300mm
Probe: Probe sockets: 2
Color: Black
Interface: VGA,PAL,USB
Unità vendibili | : | Set/Sets |
Tipo pacchetto | : | Cartone |
680 Il sistema diagnostico ad ultrasuoni Doppler a colori digitali completo adotta la tecnologia di base degli Stati Uniti. È una sorta di sistema di imaging ad ultrasuoni basato su PC e front-end ad ultrasuoni combinati con tipi di tecnologia avanzata di elaborazione delle immagini in patria e all'estero. 680 Il sistema diagnostico ad ultrasuoni Doppler a colori digitali completo non viene solo applicato a tipi di diagnosi ad ultrasuoni generali come sistema ad ultrasuoni in bianco e nero, ma viene anche applicato alla diagnosi con alta qualità dell'immagine come CVD e così via. Funzionalmente, è dotato delle funzioni di scansione delle immagini, misurazione, calcolo, display, query, marchio del corpo, annotato, stampa, archiviazione delle cartelle cliniche, modifica del rapporto di ispezione, impostazioni di sistema, ecc. Supporta DICOM (imaging digitale e comunicazione in Medicina) Protocollo, che è uno standard di imaging medico ampiamente accettato dal mondo. È possibile accedere facilmente alla comunicazione dati e informazioni. Può anche connettersi al sistema di archiviazione e comunicazione PACS ((come terminale. PACS è un'archiviazione di immagini mediche e
Sistemi di comunicazione, che facilita notevolmente il sistema di gestione della rete dell'ospedale.
È conveniente per la diagnosi remota. La macchina è potente, conveniente e facile da usare e supporta B, B/B, B/4B, B/M, B/PWD, CFM, CDE, B/CFM/D. Nel frattempo, il displayer può essere spostato da su e giù, anteriore e posteriore, a sinistra e a destra, che è davvero conveniente
I nostri prodotti:
Scanner ad ultrasuoni in bianco e nero
Scanner ad ultrasuoni Doppler a colori
Scanner ad ultrasuoni veterinari
Depth |
≥300mm |
Lateral Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
Axial Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
Blind Area |
≤4 mm |
Geometry Position Precision |
horizontal≤5% vertical≤5% |
Adjustment parameters of color blood flow image |
Doppler frequency, sampling frame position and size, baseline, color gain, deflection angle, wall filtering, cumulative times, etc |
Signal processing |
With dynamic filtering and quadrature demodulation With total gain adjustment Gain adjustment: 8-segment TGC The total gain of Type B, Type C and Type D can be adjusted respectively B/W image gain and color blood flow gain are adjustable respectively |
Doppler |
Doppler baseline adjustment level 6 Pulse repetition frequency can be adjusted separately: CFM PWD With D linear speed regulation |
Digital beam forming |
Continuous dynamic focusing of digital beam forming image Full range dynamic aperture of image Dynamic tracing of the whole image Weighted Sum of Image Whole Process Receiving Delay Support half step scanning and ± 10 ° linear receiving deflection angle Multi beam parallel processing technology |
Basic measurement and calculation function |
Basic measurement in mode B: distance, angle, perimeter and area, volume, stenosis rate, histogram, cross-section |
|
Basic measurement of M-mode: heart rate, time, distance and speed |
|
Doppler measurement: time, heart rate, speed, acceleration |
Gynecological measurement and calculation function |
Measurement and calculation of uterus, left ovary, right ovary, left follicle, right follicle, etc |
Obstetric measurement and calculation function |
G.A, EDD, BPD-FW, FL, AC, HC, CRL, AD, GS, LMP,HL,LV,OFD |
Urology measurement and calculation function |
Measurement and calculation of left kidney, right kidney, bladder, residual urine volume, prostate, prostate specific antigen predicted value PPSA, prostate specific antigen density PSAD, etc |
Product Size |
289×304×222mm |
Carton Size |
395×300×410mm |
N.W./ G.W. |
6kg/ 7kg |